bfd:IfKaP
Interface Keepalive Policy
Telemetry Sensor Path(s)
Configurable Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | PERMITTED VALUES | 
|---|---|---|---|
| detectMult | bfd:IfDetectMult (scalar:UByte)  | 
Detection Multiplier. This is the desired detection time multiplier for BFD packets on the local system. | RANGE: [0 , 50] DEFAULT: 3  | 
| echoRxIntvl | bfd:EchoRxIntvl (scalar:Uint16)  | 
Echo Rx Interval. This is the minimum interval, in ms, between received BFD echo packets that this system is capable of supporting. | RANGE: [0 , 999] DEFAULT: 50  | 
| minRxIntvl | bfd:IfMinRxIntvl (scalar:Uint16)  | 
Required Minimum RX Interval. This is the minimum interval, in ms, between received BFD control packets that this system is capable of supporting. | RANGE: [0 , 999] DEFAULT: 50  | 
| minTxIntvl | bfd:IfMinTxIntvl (scalar:Uint16)  | 
Desired Minimum TX Interval.This is the minimum interval, in ms, that the system would like to use when transmitting BFD control packets. | RANGE: [0 , 999] DEFAULT: 50  | 
Internal Properties 
| PROPERTY NAME | DATA TYPE | DESCRIPTION | POSSIBLE VALUES | 
|---|---|---|---|
| modTs | mo:TStamp (scalar:Date)  | 
The time when this object was last modified. | SELECTION:  0     - never DEFAULT: never  | 
| status | mo:ModificationStatus (scalar:Bitmask32)  | 
The upgrade status. This property is for internal use only. | SELECTION:  2     - created  4     - modified  8     - deleted  16    - replaced  |